Skip to content
Positive Contractors · Blog
Go back

RCD Keeps Tripping? What to Do When Your RCD Trips

Jeremy HurstReviewed byJeremy Hurst, Founder

Your power has gone off in half the house, the RCD switch in the fuse board has dropped, and it either won’t go back up or keeps tripping again. This guide explains what an RCD trip is telling you, a safe step-by-step check you can do yourself without opening anything, and when to stop and call an electrician.

If you’re not sure what an RCD is, start with our guide to RCD protection explained.

First: what does an RCD trip mean?

An RCD (residual current device) watches the current going out on the live wire and coming back on the neutral. If more than a tiny amount goes missing, it has found a path to earth, so the RCD cuts the power in a fraction of a second. That path could be water in a light fitting, a faulty appliance or a damaged cable. It could also be a person.

So an RCD trip is almost always a sign of a real fault, not a fault with the RCD. The job is to find what’s leaking.

How to tell it’s the RCD that tripped

In most fuse boards the RCD is a wider switch than the others, with a small T or Test button on it. In a split-load board, there are often two RCDs, each one covering a group of circuits. If one RCD drops, every circuit in its group goes off, even though none of the smaller switches (MCBs) next to it has moved.

If one of the small switches has also dropped, that circuit is your first suspect. If your board has a separate switch for each circuit with a test button on each, those are RCBOs. See our guide on what to do when an RCBO keeps tripping.

Step-by-step: what to do when your RCD trips

You can do all of this without tools and without removing any covers.

  1. Unplug everything on the circuits the RCD covers. If you’re not sure which ones, unplug everything in the house. Switch off fixed appliances at their isolator switches too: immersion heater, electric shower, cooker, boiler spur and any outside lights.
  2. Switch off all the small breakers (MCBs) under that RCD.
  3. Reset the RCD. Push it firmly all the way up.
    • If it won’t stay up with every MCB off, stop here. The fault is close to the board or in the RCD itself. Call an electrician.
  4. Turn the MCBs back on one at a time. If the RCD trips as you switch one on, that circuit has the fault. Leave that MCB off, reset the RCD and switch the others back on so the rest of the house has power.
  5. If all the MCBs stay on, plug appliances back in one at a time, waiting a minute or so between each. When it trips, the last thing you plugged in or switched on is your prime suspect.
  6. Test the suspect appliance on another circuit. If it trips that one too, the appliance is faulty. Stop using it and get it repaired or replaced.
Warning

Never tape an RCD up, hold it on or bypass it, and never swap it for a less sensitive one. It’s tripping to protect someone from a shock or a fire.

The most common reasons an RCD trips

A faulty appliance. This is the most common cause we find. Kettles, washing machines, dishwashers, tumble dryers, immersion heaters, ovens, electric showers and old extension leads are the usual culprits. Heating elements often start leaking to earth long before they stop working.

Water and damp. If the RCD trips after rain, look at outside sockets, garden lighting, outbuildings, doorbells and security lights. If it trips after a leak, think about ceiling lights, extractor fans and switches below the leak. Keep everything off on that circuit until it’s dry and checked.

A fault on a circuit, not an appliance. If it trips with nothing plugged in, a cable may be damaged by a nail or screw, chewed by rodents in a loft, or simply old with tired insulation. This needs an electrician with a test meter.

Too much small leakage adding up. Every appliance with electronics leaks a tiny amount of current to earth. On a board where one RCD covers lots of circuits, those small amounts can add up until the RCD trips “for no reason”, often when several things are switched on at once. The fix is usually to spread the circuits over more RCDs or to fit RCBOs, not a bigger RCD.

A neutral-to-earth fault. This is a wiring fault where the neutral touches earth somewhere. It can make an RCD trip at random or when certain things come on. It needs proper testing to find.

A storm or a power cut. RCDs sometimes trip during lightning or when the power comes back after a cut. If it resets and stays on, that’s normal. If it keeps happening, get it checked.

A worn RCD. It does happen, especially with older RCDs, but it’s the least likely cause. An electrician can test it to prove whether it’s tripping too early, rather than guessing and replacing it.

RCD keeps tripping at night or at random times

Random trips are usually caused by something that switches itself on: an immersion heater on a timer, a fridge or freezer compressor, a dehumidifier, the heating coming on, or outdoor lights on a sensor. Make a note of the time each trip happens and what was running. That pattern saves a lot of time when an electrician comes to find it.

When to call an electrician straight away

  • the RCD won’t reset even with every MCB switched off
  • it trips again with everything unplugged
  • you can smell burning or see scorch marks, or hear buzzing or crackling at the board or a socket
  • a socket, switch or plug feels warm
  • the tripping started after a leak, a flood or building work
  • you’ve found the faulty circuit but not the cause

What an electrician will do

We’ll start with the pattern you’ve noticed, then test the circuits. An insulation resistance test shows which circuit is leaking to earth and roughly how badly. We then split the circuit down until we find the fault, whether that’s a damp outside light, a cable damaged behind plaster or a faulty accessory. We’ll also test the RCD itself to confirm it trips at the right current and fast enough. If the board is old or has too many circuits on one RCD, we’ll explain the options, such as a consumer unit upgrade, before any work starts.

Landlords and letting agents

A tenant reporting that “the electrics keep tripping” should be treated as a repair to arrange quickly, not something to reset over the phone. A tripping RCD is often an early sign of a fault that will show up on the next EICR anyway. We work for landlords and agents across London and Essex and send photos and test results with every job.

Need it sorted?

If your RCD keeps tripping and you can’t find the cause, our NICEIC-approved electricians can track it down. We’re based in Chigwell and cover London and Essex. See our electrical fault finding service, read more about why your electric keeps tripping, or call 020 8227 0035.

We cover London and Essex, with our own engineers working every day across Chigwell, Loughton, Buckhurst Hill, Woodford, Ilford, Romford, Brentwood and Epping.



Previous Post