This job was an HIU repair at a home in Croydon (CR0) that gets its heating and hot water from a communal heat network through a heat interface unit (HIU). Our heating engineer supplied and fitted a new heat exchanger, a new pump and a new IHTP valve, then tested both the heating and the hot water. Everything was working correctly and there were no further issues.
What was replaced
An HIU is a compact unit, usually in a cupboard, that takes heat from the building’s central plant room and passes it to the flat’s radiators or underfloor heating and its hot water taps. Three of its working parts were changed on this visit.

The plate heat exchanger. This is a stack of thin metal plates. Hot water from the heat network runs on one side and the flat’s own water runs on the other, so heat passes across without the two supplies ever mixing. Over time the narrow channels between the plates can clog with limescale or debris, which cuts the amount of heat getting through. A tired heat exchanger often shows up as lukewarm hot water or a long wait for it to warm up.
The pump. The pump pushes water around the flat’s heating circuit, through the radiators or underfloor pipes and back to the HIU. When it fails or weakens, rooms warm up slowly or not at all, even though the heat network itself is fine.
The valve. HIUs use a set of control valves to send heat where it is needed and keep temperatures steady. A valve that sticks or wears out can stop heat getting through, or make the hot water temperature swing.
With all three parts renewed, our engineer ran the heating and the hot water and checked both were working properly before leaving.

Signs your HIU needs looking at
You don’t need to know which part has failed. Call an engineer if you notice:
- no heating, no hot water, or both
- lukewarm hot water, or hot water that runs hot then cold
- radiators or underfloor heating slow to warm up when the rest of the building seems fine
- low pressure on the HIU gauge that keeps coming back after it is topped up
- water around the HIU, or new noises from the unit
Before you call, it’s worth checking that the HIU has power, that the room thermostat or programmer is calling for heat, and that neighbours in the same building have heating. If the whole block is off, the problem is usually in the plant room, and the building’s managing agent or heat network operator needs to know.
Who arranges HIU repairs?
In many blocks the HIU belongs to the flat, but in some it is maintained by the heat network operator or the managing agent. If you rent, tell your landlord or agent first. We work for homeowners, landlords and managing agents, and we send a written job report with photos when the work is done, so everyone can see what was fitted.
Our guide to HIU repairs and common faults explains more about how these units work. You can also read how we fixed underfloor heating on an HIU in Loughton, and our post on radiator cold spots, bleeding and balancing covers the heating side.
HIU repairs across London and Essex
We service and repair HIUs in newer blocks across London and Essex, from Croydon and Southwark to Canary Wharf, Camden and Loughton. See our HIU and CIU servicing and repair service and plumbing and heating service.
No heating or hot water from your HIU? Call 020 8227 0035 (Monday to Friday, 7am to 5pm) or ask for a quote.