Case Study: Electric Panel Heater Installed in Putney (SW15)

In this home in Putney (SW15), our electrician installed a new electric panel heater on the wall and left it in full working order. It’s a small job, but a common one in London homes and flats, so here’s what’s involved and what to think about if you’re considering one.

A new white electric panel heater fitted low on the wall above the skirting, with its connection unit beside it

When an electric panel heater makes sense

Panel heaters are a good fit when:

  • a room has no radiator, or the central heating doesn’t reach it well (a converted loft, a cold hallway, an extension)
  • the property has no gas, which is common in London flats
  • you want heat in one room without running the whole heating system
  • a radiator needs replacing and running new heating pipes would mean lifting floors

Modern panel heaters are slim, sit neatly above the skirting and usually have their own thermostat and timer, so each room can be set to the temperature you want.

How a panel heater is wired

A wall heater should be wired in properly, not left running from an extension lead. It’s normally connected through a fused connection unit (sometimes called a fused spur): a switched outlet with its own fuse, so the heater can be turned off at the wall and is protected if it develops a fault.

A fused connection unit fitted beside a double socket, with the heater cable running neatly down to the skirting

Before fitting, an electrician will check:

  1. The heater’s wattage against the circuit it’s going on, so you don’t overload a socket circuit that’s already busy.
  2. Where the supply comes from, and the neatest route for the cable.
  3. Clearances around the heater set out in the manufacturer’s instructions, away from curtains and furniture.
  4. That the wall can take the fixings, especially on plasterboard.

Once it’s connected, the heater is switched on and checked to make sure it heats up and the controls work.

Running costs: what to know

Electric heaters turn almost all the electricity they use into heat, but electricity costs more per unit than gas. Panel heaters work best for rooms used at set times, with the thermostat and timer set sensibly, rather than as the only heating for a whole house running all day. If you’re heating a whole flat with electric, it’s worth also looking at electric boilers and heating options.

Landlords and agents

Electric heaters are common in rented flats. Any new fixed heater added to a rental is part of the electrical installation, so it should be fitted by a qualified electrician and will be looked at on the next EICR. EICRs are from £175 + VAT.

Electricians in Putney and south-west London

We carry out heater installs, new sockets and spurs, fault finding and EICRs across Putney, Wandsworth, Fulham and the rest of south-west London. See our electrical services or our Fulham area page.

Need a heater fitted or a room that never warms up? Call 020 8227 0035 or ask for a quote.