EICR remedial work

C1, C2 and FI items from your EICR fixed by our own NICEIC-approved electricians, priced item by item and certified, so your rental passes.

Consumer unit remedial work by our electricians
Consumer unit remedial work by our electricians

EICR remedial work: fixing what the report finds

An EICR (Electrical Installation Condition Report) lists anything unsafe with a code. C1 means danger now, C2 means potentially dangerous, and FI means further investigation is needed. If a rented home gets any C1, C2 or FI, the landlord must have the work done, normally within 28 days, and get written confirmation that it is fixed.

Our NICEIC-approved electricians do this remedial work every week for landlords, letting agents and managing agents across London and Essex. We can fix items from our own EICRs or from a report by another firm. You get a fixed written price for each item first, then photos and a certificate when it is done, ready to send to your tenant and the council if needed.

The C2 items we fix most often

  • Fire-stopping at the consumer unitGaps where cables enter a metal consumer unit have to be sealed so a fire inside cannot spread. We fit glands, grommets or fire-rated putty and refix loose boards. This is the most common C2 we see in flats in Wapping, Chelsea, St John’s Wood and Southwark.
  • Old or faulty RCDsFaulty RCDs replaced, and older Type AC RCDs changed for Type A, with surge protection added where it is needed.
  • Wrong breaker for the cableFor example a 6mm² cable on a 40A breaker changed to the right 32A breaker, or three cables crammed into one breaker separated properly.
  • Overloaded or broken ring circuitsBroken rings traced and repaired, and overloaded circuits split into separate radial circuits on their own RCBOs.
  • Damaged sockets, back boxes and fittingsCracked sockets, damaged back boxes and missing blanking plates replaced, and downlights that are not fire-rated swapped for fire-rated ones.
  • Broken parts at the intakeA broken Henley block at the meter, which left live parts open to touch, replaced.
  • Old consumer unitsWhere parts for an old board are no longer made, or two old boards are in use, we fit one new consumer unit with RCBOs.

Recent remedial jobs

  • Wapping, E1WSeveral flats in one blockConsumer unit cable entries sealed and protected after EICRs, and in one flat the lighting doubled up onto a new 10A breaker and an overloaded ring split into radials with 20A RCBOs.
  • Canary Wharf, E14Faulty RCD replacedA 63A 30mA RCD that failed its test replaced in the main board.
  • East London, E1Surge protection and Type A RCDsCircuits altered to add surge protection, and Type AC RCDs upgraded.
  • Herne Hill, SE24Three cables in one breakerA radial circuit sharing a breaker with a ring separated onto its own protection.
  • Barnet, EN5Cable and breaker matchedA 40A breaker on a 6mm² circuit changed to 32A so the cable is properly protected.
  • Finsbury, EC1VDownlights replacedDownlights that did not keep the fire rating of the ceiling replaced throughout the flat.
  • Chigwell, IG7Obsolete consumer unitA board with no replacement parts available swapped for a new consumer unit.

Area and postcode district only – we never publish client names or addresses.

Related services

Good to know

NICEIC Approved ContractorGas Safe RegisterTrustMarkSafeContractorConstructionline Silver

What customers say

“I've used Positive Contractors for a range of electrical, maintenance and plumbing needs for a number of years now and they have always proven to be reliable, hard working and honest.”
Verified customer · Property manager, EC4N
“The team at Positive are incredibly thorough, quick to respond to any queries and always so helpful with any last minute emergencies. We use them regularly for a variety of trades.”
Verified customer · Property manager, W1F
“Very happy with the service provided. They were able to accommodate our preferred date and went above and beyond. Professional, helpful and reliable throughout.”
Spiro N. · Electrical testing, HA5
Read all 619 reviews on Checkatrade →

Common questions

What do C1, C2 and FI mean on an EICR?

C1 means danger is present now, C2 means potentially dangerous, and FI means further investigation is needed. C3 is only a recommendation. Any C1, C2 or FI means the report is unsatisfactory.

How long do landlords have to fix EICR items?

Normally 28 days, or sooner if the report says so. You must then get written confirmation that the work is done and send it to the tenant, and to the council if they ask.

Can you fix items from another company's EICR?

Yes. Send us the report and we will price each C1, C2 and FI item in writing. When the work is done we issue a certificate for it.

Do you need access to the whole property?

Usually only to the consumer unit and the rooms with faults. We arrange access with the tenant or agent and keep the power off for as short a time as possible.

How much does an EICR cost?

EICRs start from £175 + VAT. Remedial work is priced item by item after the report, so you only pay for what is needed.

Got an unsatisfactory EICR? Let’s get it sorted.

Tell us what you need and you’ll get a clear, written price back.

Accredited & approved

  • NICEIC Approved Contractor
  • Gas Safe Register
  • TrustMark Government Endorsed Quality
  • SafeContractor Approved
  • Constructionline Silver Member
Message us